A-01Methods

Waterproofing Methods Compared

There is no single best waterproofing. The right method depends on the surface, how much it moves, exposure to sun and standing water, and how the area will be used. Compare the common systems, see which fit each area and estimate the material for your own job.

C-01Compare

Method comparison sheet

General characteristics of each family of systems. Individual products differ, so check the data sheet of the product you are offered.

ItemALiquid urethaneBBituminous sheetCSingle-ply (PVC, TPO, EPDM)DCementitiousEAcrylic coating
Applied asBrushed, rolled or sprayed in coatsRolls torched on or self-adhered, lappedLarge sheets, welded or bonded seamsSlurry brushed or troweledRolled or sprayed in coats
SeamsSeamlessLappedWelded or tapedSeamlessSeamless
MovementGood elasticityGood with reinforcementGoodLow; flexible grades existModerate
Sun exposureNeeds a UV-stable top coatMineral or coated cap sheetMost grades made for exposureUsually coveredMade for exposure
Standing waterGood once fully curedGoodGoodUsed under tile and in tanksCheck the rating; often poor
Typical placesFlat roofs, balconies, terracesFlat roofs, foundationsLarger flat roofsBasements, wet rooms, tanksRoof restoration, walls
Main weak pointThickness depends on the applicatorLaps and upstand detailsSeam quality, puncturesCracks if the structure movesPonding water, thin coats

Read the comparison as a starting point for questions to your contractor, not as a ranking.

A-01By area

Which method for which area

Pick the area to see the methods that usually fit and the details that need extra care.

Usually fits
Liquid urethane, bituminous sheet or single-ply membranes
Extra care
Outlets and drains, upstands at parapets, penetrations and edges
Check first
Falls to the outlets and the condition of the old layer
Usually fits
Crack repair plus breathable water-repellent or elastomeric coatings; sealant at joints
Extra care
Window perimeters, sills and movement joints
Check first
Whether the wall must stay vapour-open
Usually fits
Liquid or sheet membranes made for use under tile
Extra care
Drain connection, internal corners, pipe penetrations, floor-wall junction
Check first
Falls to the drain and a flood test before tiling
Related sheet
Bathroom & shower
Usually fits
Exterior membranes where excavation is possible; cementitious or crystalline systems and drainage inside
Extra care
Wall-floor joint, tie holes, pipe entries
Check first
Whether water is under pressure or just damp
Usually fits
Liquid membranes under tile or as a walkable finish
Extra care
Door threshold height, drains, balustrade fixings
Check first
Whether water can drain away from the door

S-02Sequence

How a liquid membrane goes on

The order is the same for most liquid systems; the data sheet sets the numbers.

  1. 01/08

    Prepare the substrate

    Repair cracks and spalls, remove loose coating, dust and grease.

  2. 02/08

    Check moisture

    Measure or test that the surface is within the product's moisture limit.

  3. 03/08

    Prime

    Apply the primer the manufacturer names for that surface.

  4. 04/08

    Reinforce details

    Embed fabric at corners, drains, pipes and cracks.

  5. 05/08

    First coat

    Apply evenly; respect the recoat window.

  6. 06/08

    Second coat

    Build up to the required dry film thickness.

  7. 07/08

    Top coat

    Add UV or wear protection where the area is exposed.

  8. 08/08

    Cure before use

    Keep traffic and water off until the stated cure time has passed.

Q-01Take-off

Coating quantity estimator

Enter your area and the coverage from the product data sheet. The result updates as you type.

Input

Starting values are placeholders. Replace them with your own measurements and the product data sheet.

Take-off

Total coated area
—m²
Material before waste
—L
Waste added
—L
Containers
—pcs

Material to order

—L

Coverage on data sheets is often given per coat at a set thickness. Rough or porous surfaces take more.

General note

Read the data sheet first

Every product lists its own coverage, film thickness, recoat time, cure time, temperature and humidity limits and compatible primers. Those numbers beat any general guide, including this one.

  • —Ask the contractor which product and how many coats are in the quote
  • —Keep a copy of the data sheet with your building records
  • —If two products are combined, check that the manufacturer allows it

Q-02RFI log

Methods FAQ

RFI-01Can urethane go over an old coating?

Response

Only if the old layer is well bonded and compatible, and after the surface is cleaned and primed as the manufacturer says. Loose or blistered layers have to come off first.

RFI-02Is sheet better than liquid?

Response

Neither is better everywhere. Sheets give a known thickness but depend on their laps; liquids are seamless around complex details but depend on careful thickness control.

RFI-03Does cementitious coating stop water under pressure?

Response

Some cementitious and crystalline systems are made for water pressure from the negative side, for example in basements and tanks. Check that the product is rated for it.

RFI-04How thick should a membrane be?

Response

As thick as the data sheet requires for that use. Ask how the contractor will check it, for example by material used per area or wet film gauge readings.

Next sheet

More on membranes

Field notes on roof, wall and concrete membranes.