Shower floor and drain
The membrane must lap into the drain's clamping ring or bonded flange. A gap here sends water straight into the floor.
Shower tape mistakesA-03Bathrooms
Tile and grout are not waterproof; the membrane underneath is. This sheet shows which zones must be covered, gives you an inspection form to use before tiles go on and helps you decide between resealing, coating and a full re-waterproof.
D-02Details
Six places where bathroom leaks start. Building rules on how far the membrane must extend differ by country; follow yours.
The membrane must lap into the drain's clamping ring or bonded flange. A gap here sends water straight into the floor.
Shower tape mistakesCovered to at least the height your local rules require, with every board joint banded.
Shower walls postThe wall above the tub and the joint between tub and wall take splash water every day.
Sealing the tub jointMovement between floor and wall cracks rigid layers. Reinforcing band and flexible sealant cover it.
Every pipe through the membrane needs a sealing collar or the manufacturer's detail.
Without an upstand or a set-down floor, water on the floor runs under the door into the next room.
F-02Inspection
Use it on site before the tiler starts. Tick only what you have seen yourself, and take photos.
Pre-tile inspection · 7 items
0 / 7 ticked
Open items left. Ask for them to be fixed and photographed before any tile goes on; after tiling they are hard to check.
S-04Sequence
Liquid systems follow roughly this order; sheet systems replace the coats with bonded sheets and taped seams.
01/06
Dust-free boards or render, primer as the data sheet says.
02/06
Embed tape or fabric in the first coat at corners and board joints.
03/06
Fit sealing collars around valve bodies and pipes.
04/06
Second coat at right angles to the first, to the required thickness.
05/06
Carry the membrane past the wet area as specified.
06/06
Let it cure fully, then flood test the floor before tiling.
A-03Options
Pick the option you are weighing to see what it can and cannot do.
General note
Clear or coloured coatings over tile can help where grout is porous, but they do not replace a failed membrane under the tile. If water is already behind the tiles, or tiles sound hollow, the fix starts underneath.
Q-04RFI log
Response
Membrane makers and local rules set the period; 24 hours is common. Mark the water level, check it at the end and look at the ceiling below.
Response
Only surface problems such as joints and porous grout can be treated from the top. A failed membrane under the tile needs the tile removed. See paint over bathroom tile.
Response
Tape is for joints, corners and seams within a full system; it does not waterproof a wall on its own. Common errors are listed in waterproofing tape mistakes.
Response
When it splits, loses grip, or mould has grown under it. Check it once or twice a year; the sealing sheet has a quick check.
Next sheet
Hands-on notes on shower walls, tape and bathroom paint.